R618       *Use PDP/PDP2.0/PDH terminals as designed. Only 1 wire shall be connected to each terminal on the PDP/PDP2.0/PDH.

If multi-point distribution of circuit power is needed (e.g. to provide power to multiple PCMs and/or VRMs from 1 20A circuit), then all incoming wires may be appropriately spliced into the main lead (e.g. using an insulated terminal block, crimped splice or soldered wire splice), and the single main lead inserted into the terminal to power the circuit.

Similar Rules

Rule R620
R620       *Only use specified fuses in PDP/PDP2.0/PDH. The only fuses permitted for use in the PDP/PDP2.0/PDH are automotive blade fuses with the following values:
Rule R610
R610       *1 breaker/fuse per circuit. All circuits, with the exceptions of those listed in R615 and R617, must connect to, and have power sourced solely by, a single protected 12VDC WAGO connector pair of the PDP/PDP2.0/PDH, not the M6 cap screws.
Rule R619
R619       *Only use specified circuit breakers in PDP/PDP2.0/PDH. The only circuit breakers permitted for use in the PDP/PDP2.0/PDH are:
Rule R621
R621       *Protect circuits with appropriate circuit breakers. Each branch circuit must be protected by 1 and only 1 circuit breaker or fuse on the PDP/PDP2.0/PDH per Table 8‑3. No other electrical load can be connected to the breaker or fuse supplying this circuit with the exception of devices downstream of a Kraken X60 Powerpole adapter board (WCP-1380, RF-4003).