8.6       Power Distribution

In order to maintain safety, the rules in this section apply at all times while at the event, not just while the ROBOT is on the FIELD for MATCHES.

Similar Rules

Section 8.8
8.8       Pneumatic System
Rule R615
R615       *Power roboRIO as specified. The roboRIO power input must be connected directly to a non-switched pair of protected output terminals of a PD with a 10A fuse or circuit breaker installed. No other electrical load can be connected to the breaker or fuse supplying this circuit.
Rule R618
R618       *Use PD terminals as designed. Only 1 wire shall be connected to each terminal on the PD.
Rule R610
R610       *1 breaker/fuse per circuit. All circuits, with the exceptions of those listed in R615 and R617, must connect to, and have power sourced solely by, a single protected connector pair of the PD. Circuits must not connect to the main power input of the PD.