FRCTools
Search
⚡️
2023 - Charged Up
Heads up!
You are viewing a rule from the 2023 manual. Click here to see the latest version.
Home
2023
Rule R624
Similar Rules
Rule R622
R622 *Use appropriately sized wire. All circuits shall be wired with appropriately sized insulated copper wire (Signal Level cables dont have to be copper):
Rule R611
R611 *The Robot frame is not a wire. All wiring and electrical devices shall be electrically isolated from the Robot frame. The Robot frame must not be used to carry electrical current.
Rule R625
R625 *Dont modify critical power paths. Custom Circuits shall not directly alter the power pathways between the Robot battery, PDP/PDH, motor controllers, relays (per R503-B), motors and actuators (per R501), pneumatic solenoid valves, or other elements of the Robot control system (items explicitly mentioned in R701). Custom high impedance voltage monitoring or low impedance current monitoring circuitry connected to the Robots electrical system is acceptable, if the effect on the Robot outputs is inconsequential.
Rule R618
R618 *Use PDP/PDH terminals as designed. Only 1 wire shall be connected to each terminal on the PDP/PDH.