R622
*Use appropriately
sized wire. All circuits shall be wired with appropriately sized
insulated copper wire (
Table 8‑4 Breaker and wire sizing
Application |
Minimum Wire Size |
31 40A breaker protected circuit |
12 AWG (13 SWG or 4 mm2) |
21 30A breaker protected circuit |
14 AWG (16 SWG or 2.5 mm2) |
6 20A breaker protected circuit |
18 AWG (19 SWG or 1 mm2) |
11-20A fuse protected circuit |
|
Between the |
|
Compressor outputs from the
|
|
Between the |
|
Between the |
22 AWG (22 SWG or 0.5 mm2) |
Between the |
|
Kraken x60 Powerpole Adapter protected circuit |
|
≤5A breaker protected circuit |
|
≤10A fuse protected circuit |
|
|
24 AWG (24 SWG or .25 mm2) |
roboRIO PWM port outputs |
26 AWG (27 SWG or 0.14 mm2) |
|
28 AWG (29 SWG or .08 mm2) |
Wires that are recommended by the device manufacturer or originally attached to legal devices are considered part of the device and by default legal. Such wires are exempt from this rule.
In order to show compliance with these rules, teams should use wire with clearly labeled sizes if possible. If unlabeled wiring is used, teams should be prepared to demonstrate that the wire used meets the requirements of this rule (e.g. wire samples and evidence that they are the required size).