R620      *Only use specified fuses in PDP/PDH. The only fuses permitted for use in the PDP/PDH are mini automotive blade fuses (ATM style) with the following values:

A.     for the PDP, values matching the value printed on the device’s corresponding fuse holder and

B.     for the PDH, 15A or lower with the exception of a single 20A fuse for powering a PCM or PH.

Note that these fuses must be pressed very firmly to seat properly. Improper seating can cause a device to reboot upon impact.

Similar Rules

Rule R619
R619      *Only use specified circuit breakers in PDP/PDH. The only circuit breakers permitted for use in the PDP/PDH are:
Rule R618
R618      *Use PDP/PDH terminals as designed. Only 1 wire shall be connected to each terminal on the PDP/PDH.
Rule R622
R622      *Use appropriately sized wire. All circuits shall be wired with appropriately sized insulated copper wire (SIGNAL LEVEL cables don’t have to be copper):
Rule R610
R610      *1 breaker per circuit. All circuits, with the exceptions of those listed in R615 and R617, must connect to, and have power sourced solely by, a single protected 12VDC WAGO connector pair (i.e. the load terminals, as shown in Figure 8‑9) of the PDP/PDH, not the M6 cap screws.