R621
*Protect circuits with
appropriate circuit breakers. Each branch circuit must be protected by 1
and only 1 circuit breaker or fuse on the
Table 8‑3 Branch circuit protection requirements
Branch Circuit |
Circuit Breaker/Fuse Value |
Quantity Allowed Per Breaker |
Motor Controller |
Up to 40A |
1 |
|
Up to 40A |
No limit |
Automation Direct Relay 40A (*6M40*) |
Up to 40A |
1 |
Fans permitted per R501 and not
already part of |
Up to 20A |
No limit |
Spike Relay Module |
Up to 20A |
1 |
Automation Direct Relay 25A (*6M25*) |
Up to 20A |
1 |
|
Up to 20A |
1 |
Servo Power Module/Servo Hub |
Up to 20A |
1 |
Additional |
Up to 20A |
3 total |
Automation Direct Relay 12A (*6M12*) |
Up to 10A |
1 |
This rule does not prohibit the use of smaller value
breakers in the
Fans permitted per R501 may also be included
within