R609       *Connect main power safely. The following devices shall be connected with 6 AWG (7 SWG or 16 mm2) copper wire or larger as shown in Figure 8‑11:

A.      1 ROBOT battery

B.      a single pair of Anderson Power Products (or APP) 2-pole SB type connectors

C.      a single main 120-Amp (120A) surface mount circuit breaker (Cooper Bussman P/N CB185-120, CB185F-120, CB285-120 CB285F-120, CB285120F or Optifuse P/N 153120, 253120)

D.      a single main power distribution device (PD):

a.      CTR Electronics Power Distribution Panel (PDP) P/N am-2856, 217-4244, 14-806880,

b.      CTR Electronics Power Distribution Panel 2.0 (PDP 2.0) P/N 24-806880, WCP-1690

c.      REV Robotics Power Distribution Hub (PDH) P/N REV-11-1850

d.      AndyMark Power Distribution (AMPD) P/N am-5754

No additional devices or modifications shall be permitted with the following exceptions:

E.      Monitoring circuitry permitted by R625

F.      SB-50 to SB-120 adapters, provided they have been presented for Inspection

G.     Termination of wires with appropriate cable lugs

Figure 8‑11 Electrical connection diagram

Image showing electrical connection diagram

“SB type” refers to SB type only (e.g. SB-50, SB-120, etc.), not SBS or any other part type beginning with SB. All batteries supplied by FIRST (such as Spare Parts and international batteries) will have a red or pink SB50 connector installed which may not be removed.

The pink connectors included in the KOP mate with the red SB50 connector.

While pure copper wire is recommended, copper-clad aluminum wire is considered copper wire