R619 *Only use specified circuit breakers in a PD. The only circuit breakers permitted for use in the PD are:
A. Snap Action VB3-A Series or AT2-A, terminal style F57, 40A rating or lower,
B. Snap Action MX5-A or MX5-L Series, 40A rating or lower,
C. REV Robotics ATO auto-resetting breakers 40A rating or lower,
D. CTR Electronics ATO auto-resetting breakers 40A rating or lower, and
E. Any ATM circuit breaker with value less than or equal to the fuses permitted per R620.