R703       *Use specific Ethernet port for roboRIO. The roboRIO Ethernet port must be connected as specified:
Rule R617
R617       *Power radio as specified – Part 2. The device supplying power to the wireless bridge per R616 must be connected directly to a non-switched pair of protected output terminals of a PD with a 10A fuse or circuit breaker installed with the exception of the PDP 1.0 shared VRM/PCM pairs which may be protected with a 20A fuse or circuit breaker. No other electrical load can be connected to the breaker or fuse supplying this circuit with the exception of a single PCM if using the shared VRM/PCM ports of a PDP 1.0.
Rule R626
R626       *VH-109 PoE passthrough. The VH-109 PoE output may be used only under the following conditions:
Rule R615
R615       *Power roboRIO as specified. The roboRIO power input must be connected directly to a non-switched pair of protected output terminals of a PD with a 10A fuse or circuit breaker installed. No other electrical load can be connected to the breaker or fuse supplying this circuit.