R703       *Use specific Ethernet port for roboRIO. The roboRIO Ethernet port must be connected as specified:

A.      For VH-109 v1.5 radios: to the port labeled “RIO” either directly, via a Cat5 Ethernet pigtail, or via a passive PoE injector cable or adapter.

B.      For VH-109 v1.0 radios (either directly or via Cat5 Ethernet pigtail):

a.      to the radio port labeled “RIO” via a passive PoE injector cable or adapter (whether or not it is used to power the radio), or an Ethernet cable with the appropriate wires removed on the roboRIO end. All wires or adapters used must be fully insulated, or

b.      to the radio port labeled “AUX 1” or “AUX 2” with the corresponding DIP switch in the off (default) position.

C.      For OM5P radios (China events only): to the wireless bridge port labeled “18-24v PoE” (either directly, via a network switch, via an RPM, or via a Cat5 Ethernet pigtail).

Note: Placing a switch between the roboRIO and radio may impede the ability for FIELD STAFF to troubleshoot roboRIO connection issues on the FIELD. Teams may be asked to connect directly between the radio and the roboRIO as part of troubleshooting efforts.

If not using the “RIO” port of the VH-109 1.0, it is strongly recommended to cover the port to prevent accidental damage to devices such as laptops which may occur if attached to this port.

Similar Rules

Rule R616
R616       *Power radio as specified – Part 1. The wireless bridge (radio) power must be connected based on the radio type:
Rule R702
R702       *Communicate with the ROBOT with the specified radio. 1 Vivid Hosting wireless bridge (P/N: VH-109, WCP-1538), that has been configured with the appropriate encryption key for your team number at each event, is the only permitted device for communicating to and from the ROBOT during the MATCH. Events held in China are the exceptions to this rule and must use an OpenMesh (P/N: OM5P-AN or OM5P-AC) radio.
Rule R903
R903       *Connect FMS Ethernet directly to the OPERATOR CONSOLE. Devices hosting the Driver Station Software must only interface with the FMS via the Ethernet cable provided at the DRIVER STATION (e.g. not through a switch). Teams may connect the FMS Ethernet cable to the device running the Driver Station Software directly via an Ethernet pigtail, or with a single-port Ethernet converter (e.g. docking station, USB-Ethernet converter, Thunderbolt-Ethernet converter, etc.). The Ethernet port on the OPERATOR CONSOLE must be easily and quickly accessible.
Rule R710
R710       *Only specified modifications to control system devices permitted. The Driver Station Software, roboRIO, PD, PCM(s)/PH(s), VRM(s)/RPM(s), RSL, 120A breaker, motor controllers, MXP devices used to control actuators per R713-C, relay modules (per R504-B), wireless bridge, PD breakers and fuses, Servo Power Module, Servo Hub, motor power adapter boards, and batteries shall not be tampered with, modified, or adjusted in any way (tampering includes drilling, cutting, machining, rewiring, disassembling, painting, etc.), with the following exceptions: