R619       *Only use specified circuit breakers in PDP/PDH. The only circuit breakers permitted for use in the PDP/PDH are:

A.     Snap Action VB3-A Series or AT2-A, terminal style F57, 40A rating or lower,

B.     Snap Action MX5-A or MX5-L Series, 40A rating or lower, and

C.     REV Robotics ATO auto-resetting breakers 40A rating or lower.

Similar Rules

Rule R621
R621       *Protect circuits with appropriate circuit breakers. Each branch circuit must be protected by 1 and only 1 circuit breaker or fuse on the PDP/PDH per Table 9‑3. No other electrical load can be connected to the breaker or fuse supplying this circuit.
Rule R620
R620       *Only use specified fuses in PDP/PDH. The only fuses permitted for use in the PDP/PDH are mini automotive blade fuses (ATM style) with the following values:
Rule R610
R610       *1 breaker per circuit. All circuits, with the exceptions of those listed in R615 and R617, must connect to, and have power sourced solely by, a single protected 12VDC WAGO connector pair (i.e. the load terminals, as shown in Figure 9‑10) of the PDP/PDH, not the M6 cap screws.
Rule R618
R618       *Use PDP/PDH terminals as designed. Only 1 wire shall be connected to each terminal on the PDP/PDH.