R505      *Don’t overload controllers. Each power regulating device may control electrical loads per Table 8‑2. Unless otherwise noted, each power regulating device shall control 1 and only 1 electrical load.

Table 8‑2 Power regulating device allotments

Electrical Load

Motor Controller

Relay Module

Pneumatics Controller

AndyMark RedLine Motor

Banebots

CIM

REV Robotics NEO Brushless

REV Robotics NEO 550

REV Robotics NEO Vortex

VEX Mini-CIM

WCP RS775 Pro

Yes

No

No

AndyMark 9015

VEXpro BAG

Yes
(up to 2 per controller)

No

No

AndyMark PG

KOP Automotive Motors

NeveRest

Snow Blower Motor

REV Robotics HD Hex

Yes
(up to 2 per controller)

Yes

No

Linear Actuator

Yes (20A breaker max)

Yes (20A breaker max)

No

CTR Electronics/VEX Falcon 500

Nidec Dynamo BLDC Motor w/ Controller

Playing With Fusion Venom

WCP Kraken X60

Yes
(integrated controller only)

No

No

Compressor

No

Yes

Yes

Pneumatic Solenoid Valves

No

Yes
(multiple)

Yes
(1 per channel)

Electric Solenoids

Yes
(multiple)

Yes
(multiple)

Yes
(1 per channel)

CUSTOM CIRCUITS

Yes
(multiple)

Yes
(multiple)

Yes
(multiple)