R617 *Power radio as specified – Part 2. The device
supplying power to the wireless bridge per R616 must be
connected to either:
A.
the designated supply terminals at the end of the PDP, as shown in Figure 8‑13. With the exception of a single CTR
Electronics Pneumatics Control Module (PCM, P/N am-2858) or REV
Robotics Pneumatic Hub (PH, P/N REV-11-1852), no other
electrical load shall be connected to these PDP terminals,
Figure 8‑13
VRM, PCM, RPM, and Radio power source on a PDP

B.
the terminals of the non-switchable fused channels on the PDH (20,21,22)
with a 10A fuse or circuit breaker installed in the associated fuse holder. No
other electrical load shall be connected to that channel, or
Figure 8‑14 VRM/RPM/Radio power source on a PDH

C.
directly to the terminals of any channel on the PDP 2.0 with a 10A fuse
or circuit breaker installed in the associated fuse holder.
Figure 8‑15 VRM/RPM/Radio power source on a PDP 2.0