Rule R610
R610 *1 breaker per circuit. All circuits, with the exceptions of those listed in R615 and R617, must connect to, and have power sourced solely by, a single protected 12VDC WAGO connector pair (i.e. the load terminals, as shown in Figure 9‑10) of the PDP/PDH, not the M6 cap screws.
Rule R625
R625 *Dont modify critical power paths. Custom Circuits shall not directly alter the power pathways between the Robot battery, PDP/PDH, motor controllers, relays (per R503-B), motors and actuators (per R501), pneumatic solenoid valves, or other elements of the Robot control system (items explicitly mentioned in R701). Custom high impedance voltage monitoring or low impedance current monitoring circuitry connected to the Robots electrical system is acceptable, if the effect on the Robot outputs is inconsequential.
Rule R611
R611 *The Robot frame is not a wire. All wiring and electrical devices shall be electrically isolated from the Robot frame. The Robot frame must not be used to carry electrical current.
Rule R619
R619 *Only use specified circuit breakers in PDP/PDH. The only circuit breakers permitted for use in the PDP/PDH are: